If you are buying or replacing fire doors, you will come across the ratings FD30 and FD60. The number is the length of time, in minutes that the door is there to hold back fire. This guide explains what each rating means and how to find out which one your building needs.
What Do FD30 and FD60 Mean?
An FD30 door offers a minimum of 30 minutes of fire protection. An FD60 door is designed to offer at least 60 minutes (LFS fire door manufacture).
The rating applies to the door assembly as a whole, because the assembly is tested as one unit. This includes the door leaf, the frame, the ironmongery and the glazing system. Fire doors are tested using a published British Standard (BS) testing method, either BS 476-22 or the European equivalent, BS EN 1634-1. The test shows how long the door can hold back fire. Itโs performance is only assured if all compatible components, such as frames and seals are used.
Some doors have an S after the rating, appearing as FD30S. Our guide to intumescent strips and smoke seals explains what that means.ย
How Do You Tell Which Rating A Door Has?
Every fire door should carry a permanent label or plug. It shows the doorโs rating and its certification number. All fire doors must have the proof of performance for the rating they carry.
Which Rating Does your Building Need?
The rating a fire door needs depends on where it is in the building. Approved Document B, the government guidance on fire safety in buildings, points to different periods being required for different situations.
To find out which rating applies to your door:
Find the buildingโs fire strategy
The fire strategy sets out where fire doors are required. Itโs a plan drawn up by the architect and kept with the buildingโs operations and maintenance manuals.
If there isnโt one, commission one
Ask a fire engineer to produce a fire strategy for the building. The institute of Fire Engineers has a member directory that can help you find one to help.
Check for rooms with a special fire risk
The guidance gives examples including plant rooms, electrical intake rooms, kitchens, science labs and rooms which store chemicals and fuel. It suggests these ordinarily have higher-rated doors, which contain fire for longer.
Check your fire risk assessment
It should also confirm that the fire doors are effective and have been tested.
What Should You Ask Before You Order?
Which rating does the buildingโs fire strategy specify for this specific door?
Does the door carry a label or plug showing that rating and certification number?
Is the proof of performance for the complete assembly, including the frame, seal and ironmongery?
Talk To Us About Your Project
We manufacture FD30 and FD60 (30 and 60 minute) fire doors in-house at our Kent facility. If you are not sure which rating you need, get in touch with us or call 0800 035 6827. You can also read more about our fire door manufacture.